Transpiration cooling of a cylinder in crossflow : an experimental investigation

Public Deposited
Resource Type
Creator
Abstract
  • Experiments have been carried out in air on a two-inch diameter porous cylinder to determine the effect of air injection on heat transfer from a cylinder in crossflow. The Reynolds number based on cylinder diameter and free stream conditions was varied from 31,200 to 119,000 for the dimensionless injection parameter, f , = (p V /Poo Uoo )//Re(q>range of approximately 0.5 to 2.5; the flow being incompressible (U = 121 Ft/Sec). The to ^ °°,max heat transfer results at the forward stagnation point are in good agreement with the two-dimensional stagnation flow theory. Local heat transfer parameter Nu,f/ /^Re,ris presented as a function of angular location. The results agree well with the data of other investigators. A slight effect of Reynolds number on the heat transfer parameter is observed.

Subject
Language
Publisher
Thesis Degree Level
Thesis Degree Name
Thesis Degree Discipline
Identifier
Access Rights
Rights Notes
  • Copyright © 1971 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.

Date Created
  • 1971